fnc_startRefuel.sqf 2.8 KB

1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586
  1. params["_vehicle"];
  2. private _rate = 10;
  3. private _attached = _vehicle getVariable["RD501_mc_attached_large", objNull];
  4. _vehicle setVariable["RD501_mc_stop_refuel", false, true];
  5. _maxFuelSource = getNumber (configFile >> "CfgVehicles" >> typeOf _vehicle >> "fuelCapacity");
  6. _maxFuelTarget = getNumber (configFile >> "CfgVehicles" >> typeOf _attached >> "fuelCapacity");
  7. private _firstTick = 0;
  8. if (isMultiplayer) then
  9. {
  10. _firstTick = serverTime;
  11. } else
  12. {
  13. _firstTick = time;
  14. };
  15. hint "Refueling started";
  16. _vehicle setVariable["RD501_mc_lastRefuelTick", _firstTick, true];
  17. _vehicle setVariable["RD501_mc_nextRefuelUpdate", 0.1, true];
  18. [{
  19. params ["_args", "_pfID"];
  20. _args params ["_target", "_source", "_rate", "_maxFuelSource", "_maxFuelTarget"];
  21. if (!alive _source || {!alive _sink}) then
  22. {
  23. _vehicle setVariable["RD501_mc_lastRefuelTick", nil, true];
  24. _vehicle setVariable["RD501_mc_nextRefuelUpdate", nil, true];
  25. [_pfID] call CBA_fnc_removePerFrameHandler;
  26. };
  27. if (_source getVariable["RD501_mc_stop_refuel", false]) then
  28. {
  29. hint "Refueling stopped";
  30. _vehicle setVariable["RD501_mc_lastRefuelTick", nil, true];
  31. _vehicle setVariable["RD501_mc_nextRefuelUpdate", nil, true];
  32. [_pfID] call CBA_fnc_removePerFrameHandler;
  33. };
  34. private _currentTime = 0;
  35. if (isMultiplayer) then
  36. {
  37. _currentTime = serverTime;
  38. } else
  39. {
  40. _currentTime = time;
  41. };
  42. private _target_fuel = (fuel _target) * _maxFuelTarget;
  43. private _source_fuel = (fuel _source) * _maxFuelSource;
  44. private _deltaT = _currentTime - (_source getVariable["RD501_mc_lastRefuelTick", 0]);
  45. private _transfer = _rate * _deltaT;
  46. private _target_new_fuel = ((_target_fuel + _transfer) / _maxFuelTarget);
  47. private _source_new_fuel = ((_source_fuel - _transfer) / _maxFuelSource);
  48. private _last_update = _source getVariable["RD501_mc_nextRefuelUpdate", 0];
  49. if (_target_new_fuel >= 1.0) then
  50. {
  51. _target_new_fuel = 1.0;
  52. hint "Refueling complete";
  53. _vehicle setVariable["RD501_mc_lastRefuelTick", nil, true];
  54. _vehicle setVariable["RD501_mc_nextRefuelUpdate", nil, true];
  55. [_pfID] call CBA_fnc_removePerFrameHandler;
  56. } else
  57. {
  58. if (_target_new_fuel >= _last_update) then
  59. {
  60. _last_update = round(_target_new_fuel * 10) / 10;
  61. hint format ["Refueling at %1 percent", str (_last_update*100)];
  62. _source setVariable["RD501_mc_nextRefuelUpdate", _last_update+0.1, true];
  63. };
  64. };
  65. ["RD501_mc_set_fuel", _target_new_fuel, _target] call CBA_fnc_targetEvent;
  66. _source setFuel _source_new_fuel;
  67. _source setVariable["RD501_mc_lastRefuelTick", _currentTime, true];
  68. }, 1, [_attached, _vehicle, _rate, _maxFuelSource, _maxFuelTarget]] call CBA_fnc_addPerFrameHandler;